01340-8

SUBMITTALS
OPERATIONS AND MAINTENANCE MANUAL CERTIFICATION FORM
PROJECT: CONTRACTOR'S PROJ. NO:
CONTRACTOR: ENGINEER'S PROJ. NO:
ENGINEER:
O&M - OM-
NUMBER: SPECIFICATION SECTION SEQUENTIAL NUMBER
OR DRAWING NO: (& ALPHA SUFFIX FOR
RESUBMITTAL)
DESCRIPTION:
MANUFACTURER:

The above referenced operations and maintenance manual has been reviewed by the undersigned
and I/we certify that the manual is customized as needed for this project, is suitable for mounting

Finance Committee - Agenda - 6/7/2017 - P466

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P466

SUBMITTAL CERTIFICATION FORM

PROJECT: CONTRACTOR'S PROJ. NO:

CONTRACTOR: ENGINEER'S PROJ. NO:

ENGINEER:

SHOP -

DRAWING SPECIFICATION SECTION SEQUENTIAL NUMBER

NUMBER: OR DRAWING NO: (& ALPHA SUFFIX FOR
RESUBMITTAL)

DESCRIPTION:

MANUFACTURER:

The above referenced submittal has been reviewed by the undersigned and I/we certify that the
material and/or equipment meets or exceeds the project specification requirements with

[.] NO DEVIATIONS
or

Finance Committee - Agenda - 6/7/2017 - P465

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P465

01340-6
SUBMITTALS

for; however, Engineer requires that all comments will be addressed by the
Contractor, unless otherwise notified in writing prior to execution of the
relevant work.

Finance Committee - Agenda - 6/7/2017 - P464

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P464

01340-5
SUBMITTALS

certification that equipment, accessories and shop painting meet or exceed the
Specification requirements.
7. Where specified, manufacturer's guarantee.

C. Requirements for Electronic Submittals:

1. Each individual shop drawing or O&M submittal shall be contained in one
PDF.

2. The first page of the PDF shall be the Submittal Certification Form as
described above.

Finance Committee - Agenda - 6/7/2017 - P463

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P463

01340-4
SUBMITTALS

Maintenance Manual submitted, the Contractor shall provide a copy of the complete
Operations and Maintenance Manual Certification Form (copy provided for the
Contractor's use at the end of this Specification Section) signed by both the
Contractor and the Manufacturer.

1.5 MANUFACTURER'S CERTIFICATES

A. Prior to accepting the installation, the Contractor shall submit manufacturer's
certificates for each item specified.

Finance Committee - Agenda - 6/7/2017 - P462

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P462

01340-3
SUBMITTALS

the Owner, shall do all work necessary to make such modifications.

Finance Committee - Agenda - 6/7/2017 - P461

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P461

01340-2
SUBMITTALS

Finance Committee - Agenda - 6/7/2017 - P460

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P460

01340-1
SECTION 01340

SUBMITTALS

PART 1 - GENERAL

1.1 DESCRIPTION

A.

B.

Work Included:

1. Submit to the Engineer, Shop Drawings, Operation and Maintenance Manuals,
Manufacturers' Certificates, Project Data, and Samples required by the
Specification Sections.

Related Work Specified Elsewhere:

1. Construction Schedules: Section 01310

2. Project Record Documents: Section 01720

3. General Conditions: Section C.

1.2 SHOP DRAWINGS

A.

Finance Committee - Agenda - 6/7/2017 - P459

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P459

01320-5
SAFETY AND HEALTH PLAN

TABLE 3
NASHUA WASTEWATER TREATMENT FACILITY
CHEMICAL HAZARD LISTING

Location Chemical Hazard
. er Sodium Hypochlorite, Sodium Bisulfite,
Operations Building Sodium Hydroxide, Hydrogen Peroxide

Note: This list has been provided by the Owner based upon their knowledge of the site and may
not include all site hazards. Its intent is to aid the Contractor in determining the magnitude of
effort needed to fulfill the safety and health requirements of this Contract.

END OF SECTION

13089K

Finance Committee - Agenda - 6/7/2017 - P458

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P458

01320-4
SAFETY AND HEALTH PLAN

1.4 SITE-SPECIFIC INFORMATION
A. <A copy of the City of Nashua, New Hampshire Wastewater Treatment Facility

Confined Space Entry Program is included in Appendix A of these specifications.
B. Refer to Tables 1, 2 and 3 below.

TABLE 1

NASHUA WASTEWATER TREATMENT FACILITY
CONFINED SPACE LISTING

Confined Space Location

Hazard Description

Influent Channels

Possible lack of oxygen or presence of explosive or
hazardous gases - Hydrogen Sulfide.