Skip to main content

Main navigation

  • Documents
  • Search

User account menu

  • Log in
Home
Nashua City Data

Breadcrumb

  1. Home
  2. Search

Search

Displaying 19331 - 19340 of 38765

Finance Committee - Agenda - 6/19/2019 - P58

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
58
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…

° Community Development
City of Nashua Planning and Zoning
. oa Building Safety
Community Development Division Code Enforcement

Urban Programs

City Hall, 229 Main Street, PO Box 2019 Conservation Commission
Nashua, New Hampshire 03061-2019 Transportation
www.nashuanh.gov FAX

589-3095
589-3090
589-3080
589-3100
589-3085
589-3105
880-0100
589-3119

Date: June 10, 2019

To: John Griffin, CFO; Daniel Kooken, Purchasing Manager

From: Sarah Marchant, Community Development Division Director
Re: Sole Source Otterbine River Fountains

The Community Development Division in partnership with Public Works has been working to
replace the now defunct fountain in the Nashua River with a new fountain and two additional
fountains over the past couple of years. As part of the Downtown Riverfront Master Plan the
City determined fountains with light would be an excellent way to help attract pedestrians and
boaters to our riverfront and help highlight its role in our downtown.

The City put out two separate bids for electrical upgrades and river fountains (RFP0365-013018
and RFP0365-111918) in 2018. Neither bid resulted in acceptable responses. To move the
project along Parks and Recreation hired Johnson Electric to install electrical upgrades on both
sides of the river to support the new fountain and additional fountains proposed by the riverfront
plan between the Cotton Mill and Main Street bridges.

In working with Lumen Studio, Inc the City’s Riverfront Lighting Designer and Halvorson
Design Partnership the firm that supported the creation of the Downtown Riverfront Plan, the
City is requesting to install up to three 5 HP Otterbine Fountains at a cost of $52,103.70. These
fountains will have a 4-light LED set and wind control, and we hope to have them installed by
early August.

Page Image
Finance Committee - Agenda - 6/19/2019 - P58

Finance Committee - Agenda - 6/19/2019 - P59

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
59
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…

| turf products QUOTE

157 Moody Road @ PO Box 1200 e Enfield, CT 06083

PreparedFor: City of Nashua - RIVERFRONT Quote #: 354CON41619-5PH
229 Main Street Quoted Date: 05/31/19
Nashua, NH 03060 Prepared By: Bill Conley

bconley@turfproductscorp.com

(860) 253-7832

5 HP OTTERBINE FOUNTAINS

Product Number Description Unit Price Extended
OTT-01-0015-216 OTTERBINE MOTOR UNIT, S5HP 230V/1PH MOTOR 3 ea S$ 6,456.13 $ 19,368.39
OTT-18-0041 OTTERBINE PHOENIX SPRAY PATTERN 3 ea S$ 1,193.17 $ 3,579.51
OTT-34-0002 OTTERBINE 8/3 POWER CABLE WITH PLUG 25 ft $ 4.38 S$ 109.50
OTT-34-0002 OTTERBINE 8/3 POWER CABLE WITH PLUG 25 ft $ 4.38 S$ 109.50
OTT-34-0002 OTTERBINE 8/3POWER CABLE WITH PLUG 25 ft 5$ 4.38 S$ 109.50
TPC-1-207C 3M #82/A2 WATERPROOF SPLICE KIT 3 ft $ 58.51 $ 175.53
OTT178-017 OTTERBINE PLUG END PROTECTOR (FOR STORAGE) 3 ea S$ 21.23 $ 63.69
OTT-01-0004 WIND CONTROL FOR POWER CONTROL CENTER 3 ea $ 2,207.61 S$ 6,622.83
OTT-02-0040-004 OTTERBINE 4 LIGHT SET RGBW LED 40W 60Hz 3 ea S 5,883.25 $ 17,649.75
OTT-34-0019 12/5 LIGHT KIT UNDERWATER POWER CABLE 300 ft $ 4.02 S$ 1,206.00
OTT-34-0019 12/5 LIGHT KIT UNDERWATER POWER CABLE 275 ft S$ 4.02 S$ 1,105.50
OTT-34-0019 12/5 LIGHT KIT UNDERWATER POWER CABLE 200 FT 5$ 4.02 5 804.00

SubTotal: $ 50,903.70
Estimated Shipping: S$ 1,200.00
TOTAL PRICE $ 52,103.70
Notes:

- Each power cable will be 25' long and include plug end for Otterbine motor unit. Customer will supply remaining #8 underwater cable back to
power control centers, which will require splicing to the supplied cable. Estimated total lengths from fountain to corresponding power control
center, including water depth factor: 275' (furthest west of Main St bridge), 300' (closest west of Main St bridge), 200' (east of Main St bridge).

- Power Control Unit should be installed as close to the water edge as possible for maximum GFI protection.

'. Pricing DOES NOT include any installation costs.

Page Image
Finance Committee - Agenda - 6/19/2019 - P59

Finance Committee - Agenda - 6/19/2019 - P60

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
60
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…

www.otterbine.com/phoenix

»

»

»

»

»

»

»

© PHOENIX

AERATING FOUNTAIN

Most energy efficient system in the industry.
5 year all-inclusive warranty.

Operates in 30in or 75cm of water. (No additional depth
needed when adding LED lights; additional 10in or 26cm
required if adding high voltage lights.)

Complete package includes assembled unit, power
control center, and cable. (No PCC for 50HZ.)

Power control center comes standard with surge
arrestor, timer and GFCI (Exc: optional EPD for 460V.)

Cable quick disconnect standard.

Safety tested and listed with ETL & ETL-C, conforming to
UL standards; and carries a 3rd party listing with CE.

Effectively controls algae, aquatic weeds, and foul odors;
while deterring insects and insect breeding.

Published results from 3rd party testing verify highest
oxygen transfer and pumping rates in the industry.

Product specifications and CADs can be found online through
www.otterbine.com or www.caddetails.com.

We Guarantee that
You'll Love Your Pattern

Manufactured by: Otterbine® Barebo, Inc. | 3840 Main Road East} Emmaus, PA 18049 U.S.A! PH: 610-965-6018

PRODUCT ILLUSTRATION

1.

High-tech thermal plastic pumping chambers are
staged to allow for easy interchange.

2. Rugged low visibility closed cell foam filled float
includes handles and protective pockets for lights
when applicable.

3. Industrial strength thermal plastic screen helps keep
debris out of the unit.

4. — Electrical quick disconnect is part of the upper plate
to prevent damage.

5. Mixed flow pumping system achieves maximum
pumping capacities.

6. Oil cooled, efficient 3450/2875 RPM custom
built motor incorporates a g-type seal to ensure
dependability and long life.

7. Corrosion resistant, durable 18 gauge/316 grade
stainless steel motor housing.

60 HZ 1 HP 2 HP 3 HP 5 HP

Spray upper: 8 uprer: 11 uprer: 15 upper: 18

Height (ft) Lower: 4 Lower: 6 Lower: 9 Lower: 10

Spray upper: 2 upper: 2 upper: 3 upPER: 3,

Diam. (ft) tower: 14 Lower: 20 Lower: 28 Lower: 34

GPM 150 210 275 400

Volt/Ph/Amp | 115/1/15 | 230/1/12.4 | 230/1/14 230/1/23

3450@60hz 230/1/7.5 230/3/8.6 | 230/3/13.4

460/3/4.3 460/3/7.2

Page Image
Finance Committee - Agenda - 6/19/2019 - P60

Finance Committee - Agenda - 6/19/2019 - P61

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
61
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…
Page Image
Finance Committee - Agenda - 6/19/2019 - P61

Board Of Aldermen - Minutes - 8/9/2016 - P2

By dnadmin on Sun, 11/06/2022 - 21:34
Document Date
Tue, 08/09/2016 - 00:00
Meeting Description
Board Of Aldermen
Document Type
Minutes
Meeting Date
Tue, 08/09/2016 - 00:00
Page Number
2
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_m__080920…

Board of Aldermen Page 2
August 9, 2016

Finally | wanted to mention that an issue has come up (at 4:00 p.m. today) concerning the skateboard
park and the relocation. That has been recommended by the committee but we got a call from the
school department late saying that they think that they have to approve the relocation as well as the
Board of Public Works because this is part of a school facility or the area where this relocation where this
relocation would take place is part of a school facility. | don’t think there is a big problem because if you
approve the relocation we still have to go the Planning Board and now possibly the school department
and it looks like the preliminary indication is that the school department may be correct but it just requires
that we also in addition to the Planning Board get the School Board approval. | don’t think it’s a big
obstacle but it is something that we will work through.

| want to congratulate Alderman Clemons on his marriage.

RESPONSE TO REMARKS OF THE MAYOR

Alderman Siegel

| would ask the school department if they plan on allowing the Board of Aldermen to vote on whether or
not they can use the city’s money to appeal a decision on the custodian union. Obviously that is a
rhetorical question but | am a little concerned about that.

| would like to also congratulate my colleague, Alderman Clemons, on his recent marriage.
RECOGNITION PERIOD — None
READING MINUTES OF PREVIOUS MEETINGS AND PUBLIC HEARING

MOTION BY ALDERMAN WILSHIRE THAT THE MINUTES OF THE BOARD OF ALDERMEN
MEETINGS OF JULY 12 AND JULY 25, 2016, AND THE PUBLIC HEARING CONDUCTED BY THE
BUDGET REVIEW COMMITTEE ON JULY 25, 2016, BE ACCEPTED, PLACED ON FILE, AND THE
READINGS SUSPENDED

MOTION CARRIED

COMMUNICATIONS

MOTION BY ALDERMAN CARON THAT ALL COMMUNICATIONS BE READ BY TITLE ONLY
MOTION CARRIED

From: Mayor Jim Donchess
Re: Contract Award to Emergency Communications Network

MOTION BY ALDERMAN CARON TO ACCEPT, PLACE ON FILE AND AWARD THE CONTRACT
TO EMERGENCY COMMUNICATIONS NETWORK IN THE AMOUNT OF $22,000
MOTION CARRIED

From: Mayor Jim Donchess
Re: Purchase Lawson Upgrade for In-House Hosting

MOTION BY ALDERMAN COOKSON TO ACCEPT, PLACE ON FILE AND AWARD THE CONTRACTS
TO TEAM-ABSOLUTE IN THE AMOUNT OF $326,163
MOTION CARRIED

Page Image
Board Of Aldermen - Minutes - 8/9/2016 - P2

Finance Committee - Agenda - 8/3/2022 - P123

By dnadmin on Sun, 11/06/2022 - 21:46
Document Date
Thu, 07/28/2022 - 10:40
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 08/03/2022 - 00:00
Page Number
123
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__080320…

Exhibit B

Page Image
Finance Committee - Agenda - 8/3/2022 - P123

Finance Committee - Agenda - 6/19/2019 - P62

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
62
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…

Water Works
With Otterbine
ery a Sigil :

CONCEPT3
Owner's Manual

A Guide to More Dependable
Water Quality Management
With Otterbine Barebo Inc.'s
1,2, 3 & 5 Horsepower Surface Spray
Aerating Fountain

Page Image
Finance Committee - Agenda - 6/19/2019 - P62

Finance Committee - Agenda - 6/19/2019 - P63

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
63
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…

Otterbine Barebo Inc.

SAFETY INSTRUCTIONS
7 aA

PLEASE READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND USING
THIS PRODUCT. SAVE THIS MANUAL FOR FUTURE REFERENCE AND
KEEP IN THE VICINITY OF THE PRODUCT.

Frineoace

ALL ELECTRICAL WORK MUST BE PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN AND CONFORM
WITH ALL APPLICABLE ELECTRICAL SAFETY CODES
Tous travaux électriques doivent étre effectués par un électricien professionnel qualifié et conforme a tous les codes
applicables sécurité électrique

ALWAYS SWITCH OFF/DISCONNECT ALL EQUIPMENT IN THE WATER BEFORE SERVICING OR PERFORMING
ANY MAINTENANCE
Toujours éteindre I'équipement dans l'eau avant entretien ou de tout entretien

DO NOT OPERATE THE FOUNTAIN WHEN PEOPLE ARE IN THE WATER
Ne pas utiliser la fontaine quand les gens sont dans l'eau

CAUTION: KEEP HANDS CLEAR OF THE IMPELLER WHEN OPERATING!
ATTENTION: Garder les mains loin du turbine lors de utilisation!

STAY OUT OF WATER WHEN

eaurwenr sverezes) SPINNING IMPELLER

i TURBINE ROTATIVE

ELECTRICAL SHOCK HAZARD

Disconnect From Electrical Supply
When Servicing This Equipment

Unplug Or Switch Off All Appliances in The
Water Before Carrying Out Maintenance

This Product Must Be Properly Grounded

KEEP HANDS CLEAR

TENIR LES MAINS ELOIGNEE

WARNINGS
* Before entering, wading in or swimming in the water in which Otterbine Aerators or Fountains are installed, make sure
they are PHYSICALLY disconnected from their eiectricai power sources.
- Aerators located in or near garden ponds and similar locations must be equipped with Ground Fault Circuit Interrupter.

- The permissible temperature range for this equipment is -12° to 40° C/10° to 104° F.

+ Itis possible for the water to become slightly polluted in the rare case that an oil leak occurs.

* If the power cord is damaged, it must be replaced by a special cord or assembly available from Otterbine/ Barebo, Inc.
or an authorized Otterbine/Barebo, Inc. sales and service center.

- Avant d'entrer, pataugeant dans ou en nageant dans l'eau dans laquelle Aérateurs Otterbine ou fontaines sont

installées, assurez-vous qu'ils sont physiquement déconnectés de leur source d'alimentation électrique.

« Aérateurs situés dans ou a proximité des bassins de jardin et des emplacements similaires doivent etre Equipés de

disjoncteur.

- La plage de température admissible pour cet appareil est-12 0 a 40 oC/10 0 a 104 oF aux.

- ll est possible pour que l'eau devient !égérement polluées dans les rares cas ou une fuite d'huile se produit.

+ Si le cordon d'alimentation est endommagé, il doit étre remplacé par un cordon spécial ou de montage disponible a

partir Otterbine / Barebo, Inc ou une autorisation Otterbine / Barebo, les ventes Inc et centre de service.

www.otterbine.com
4 75-0073 Rev 08 60Hz Concept 3 1-800-AER8TER

Page Image
Finance Committee - Agenda - 6/19/2019 - P63

Finance Committee - Agenda - 6/19/2019 - P64

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
64
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…

Otterbine Barebo Inc.

INSPECT AERATOR EQUIPMENT

Immediately report any shipping damage to the carrier that delivered your aerator.

Inspect your aerator and verify the following:
Unit - Check the nameplate located on the housing of the aerator unit to make sure you have received the correct
horsepower and voltage aerator.

Power Control Center - Verify the PCC is compatible with the aerator unit horsepower and voltage. Refer to the electrical
specifications on the nameplate located inside on the door of the PCC.

Power Cable Assembly - Verify the correct cable gauge and length.

For proper warranty consideration return your Otterbine warranty registration card.

ELECTRICALIPCC INSTALLATION

ELECTRICAL INSTALLATION MUST BE PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN AND CONFORM
TO ALL APPLICABLE LOCAL AND NATIONAL CODES

DISCONNECT EQUIPMENT FROM ELECTRICAL SUPPLY BEFORE SERVICING OR PERFORMING MAINTENANCE
Use Only OTTERBINE power cord. Do not splice or repair the cord, replacement is necessary if damage occurs.

The standard Power Control Center includes a fiberglass NEMA 4X enclosure with twenty-four hour timer control in the
auto setting or manual control of the aerator unit, the required motor short circuit, ground fault and overcurrent protection,
surge protection, and personnel GFCI protection (except 460V 60Hz. applications). On 460V units EPD (Equipment
Protection Device) is an optional accessory to provide 5, 10 or 30 mA ground fault protection.

Caution: GFCI Protection is required. If GFCI protection is not used, serious or FATAL electrical shock may
occur.

Attention: GFCI/RCD de protection est nécessaire. Graves ou mortelles choc électrique peut se produire s'il n'est
pas utilisé.

A. Feeder

1. Proper feeder circuit protection in accordance with all applicable local and national codes must be provided to the
power control center.

2. Be certain to properly size feeder conductors to allow for no more than 5% voltage drop for the entire circuit from the
feeder source to the aerator unit. Failure to do so may damage the aerator and void product warranty.

60Hz. Electrical Specifications
HP Volts Phase | Full Load Amps

1 115 1 15.5
1 208/230 1 8.3/7.5
2 208/230 1 13.7/12.4
3 208/230 4 15.51/14
3 208/230 3 9.7/8.6
3 380 3 4.6
3 460 3 4.3
5 | 230 Only 1 23
5 208/230 3 15.1/13.4
5 380 3 7.6
5 460 3 7.2
5 575 3 5.5

B. PCC Location

1. The power control center should be mounted where easily visible from the shoreline where the aerator is located.
Important: The power control center shall not be accessible from the water.

Important: Le Centre de Contréle de la puissance ne doit pas étre accessible a partir de l'eau

www.otterbine.com
1-800-AER8TER 75-0073 Rev 08 60Hz Concept 3 5

Page Image
Finance Committee - Agenda - 6/19/2019 - P64

Finance Committee - Agenda - 6/19/2019 - P65

By dnadmin on Mon, 11/07/2022 - 13:06
Document Date
Fri, 06/14/2019 - 15:27
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 06/19/2019 - 00:00
Page Number
65
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__061920…

Otterbine Barebo Inc.

f \ a -
i
j
yo
. , ft
392.91mm 2 an
[15% inl / |
eos e |
| fe | if
; H
Bape ta i Hi
342,77 mm———+ | iH
[13/4 inl 371.48mm | Hh
fe [145ginp
OVERALL DIMENSION MOUNTING HOLE LAYOUT

Cc. PCC Mounting
1. To prevent damage to the enclosure mount the enclosure using all four (4) mounting holes.
2. Whenever possible do not mount the PCC in direct sun light.

D. PCC Cables & Connections
1. Only Otterbine Barebo, Inc. factory approved power cord is to be used from the PCC to the aeration unit with no
junction boxes or splices. Only use power cord gauges and lengths specified by Otterbine at the time of cable purchase.
(Contact your Otterbine Distributor for proper cable sizing)

2. It is recommended that all exposed cable between the PCC and the shoreline be installed in non-metallic conduit. It is
important that aerator and lighting cables be installed in individual conduits to avoid induced interference between cables
which causes random GFCI tripping.

3. Always use strain relief cord connectors to attach the Otterbine cable to the PCC.

4. Cables and conduits must only enter into the bottom of the PCC.

5. Factory connections may loosen during shipping. Verify tightness of all screw terminal connections before energizing.
6. Power input and output wiring connections are accessed from the bottom of the enclosure. The terminal blocks for the
cable connections are located behind the hinged swing panel. Loosen the captive screw on the right center of the swing
panel for access.

Terminal Torque Values: Input — 45 in/lb. Maximum, Output — 30 in/lb. Maximum

ae a

= se AUX CONTACT,
aN ,

\
‘

SWING PANEL VIEW SUB-PANEL VIEW

www.otterbine.com
6 75-0073 Rev 08 60Hz Concept 3 1-800-AER8TER

Page Image
Finance Committee - Agenda - 6/19/2019 - P65

Pagination

  • First page « First
  • Previous page ‹‹
  • …
  • Page 1930
  • Page 1931
  • Page 1932
  • Page 1933
  • Current page 1934
  • Page 1935
  • Page 1936
  • Page 1937
  • Page 1938
  • …
  • Next page ››
  • Last page Last »

Search

Meeting Date
Document Date

Footer menu

  • Contact