Finance Committee - Agenda - 6/7/2017 - P517

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P517

15051-2
POLYVINYL CHLORIDE (PVC) DRAINAGE PIPE

Finance Committee - Agenda - 6/7/2017 - P516

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P516

15051-1

SECTION 15051

POLYVINYL CHLORIDE (PVC) DRAINAGE PIPE

PART 1 - GENERAL

1.1 DESCRIPTION
A. Work Included: Furnish and install PVC drainage pipe and fittings of the type (s)
and size (s) and in the location (s) shown on the Drawings and as specified herein.
B. Related Work Specified Elsewhere: "Pipe & Pipe Fittings - General" is specified in
this Division.

12 QUALITY ASSURANCE
A. Standards:

1. Pipe and fittings (interior) shall conform to ASTM D-2665S.

Finance Committee - Agenda - 6/7/2017 - P515

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P515

3.

4.

15050-3
PIPE & PIPE FITTINGS — GENERAL

Finance Committee - Agenda - 6/7/2017 - P514

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P514

O

mimo

15050-2
PIPE & PIPE FITTINGS — GENERAL

Store materials on the project site in enclosures or under protective coverings in
accordance with manufacturer's recommendations and as required by the Engineer.
Assure that materials are kept clean and dry.

Do not store materials directly on the ground.

Follow manufacturer's specific instructions, recommendations and requirements.

PART 2 - PRODUCTS

2.1 MATERIALS

A.

Materials are specified in the following Sections in this Division.

Finance Committee - Agenda - 6/7/2017 - P513

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P513

15050-1

SECTION 15050

PIPE & PIPE FITTINGS — GENERAL

PART 1 - GENERAL

1.1

1.2

1.3

1.4

1.5

DESCRIPTION

A. Work Included: Furnish, install, support, and test pipe and pipe fittings of the type(s)
and size(s) and in the location(s) shown on the Drawings and as specified herein.

B. Related Work Specified Elsewhere (When Applicable):
1. Valves, gates, pipe hangers, pipe supports, pipe and equipment insulation,

heating, and plumbing are specified in the appropriate Sections in Division 15.

Finance Committee - Agenda - 6/7/2017 - P512

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P512

09510- 3
ACOUSTICAL CEILINGS

PART 3 - EXECUTION

3.1

3.2

INSTALLATION

A. Install in types, sizes, and layouts as shown on the Drawings.

B. Install in strict accordance with ASTM C635.

C. Install suspension systems in strict accordance with the instructions of the
manufacturer, with hangers spaced not more than 48 inches on centers in any
direction, and as otherwise required to ensure deflection not exceeding 1/360 of the
span of the members.

D. Install a hanger at each corer of all light fixtures.

Finance Committee - Agenda - 6/7/2017 - P511

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P511

09510- 2
ACOUSTICAL CEILINGS

PART 2 - PRODUCTS

2.1 MANUFACTURERS
A. Armstrong World Industries, Inc.
B. CertainTeed.
C. Or Equal.

2.2 ACOUSTICAL PANELS
A. Acoustical Ceiling Panels:

1. Product: Armstrong Fine Fissured, CertainTeed Fine Fissured, Or equal.
Edge: Square Lay-In 15/16 inch.

Color: White.

NRC: 0.55

CAC: 33

Light Reflectance: 0.85

Fire Resistance: Class A (UL)

Anti-Microbial: BioBlock+, BioSheild or Equal.

Size: 24 inches x 24 inches x 5/8 inches.

Finance Committee - Agenda - 6/7/2017 - P510

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P510

09510-1

SECTION 09510

ACOUSTICAL CEILINGS

PART 1 - GENERAL

1.1

1.2

1.3

1.4

1.5

1.6

1.7

SECTION INCLUDES

A. Suspension System.

B. Acoustical Ceiling Panels - 24 inch x 24 inch.
C. Retention Clips.

RELATED SECTIONS

A. Section 01340 - Submittals

B. Section 04200 - Unit Masonry

C. Section 06100 - Rough Carpentry

D. Division 15 - Mechanical

E. Division 16 - Electrical

REFERENCES

A. Federal Specification SS-S118

Finance Committee - Agenda - 6/7/2017 - P509

By dnadmin on Mon, 11/07/2022 - 10:24
  • Read more about Finance Committee - Agenda - 6/7/2017 - P509

07900-4

JOINT SEALERS
3.6 SCHEDULE
Sealant Type Location
S-1, S-2 or S-6 All joints and the perimeter of penetrations, except fire rated assemblies
8-2 Joints Between Exterior Concrete Pavement or Concrete Pads Around the
Building.
8-8 At Joints in Fire Rated Assemblies

END OF SECTION