OQhem erve

ENVIRONMENTAL
317 Elm Street, Milford, NH 03055 (603) 673-5440 sales@chemservelab.com

CV - PAUL D. FYFE, DIRECTOR OF OPERATIONS

Professional Experience: Over 30 years in the analytical and environmental laboratory industry with
proficient experience in virtually every aspect of instrumental analysis, sample preparation, bench
chemistry, management, as well as corporate executive experience and responsibilities. Maximizing
profit through continuous improvement techniques, profit and loss, project management, analytical
instrumentation operation, instrument troubleshooting and repair, maintaining federal and state
certifications such as TNI-NELAC, IS017025, GMP, CPSC, MADEP, NLLAP, and A2LA, 310 CMR,
and NYDOH. Company start up experience, business acquisitions, quality control and assurance,
Experience with supervision and direction of over 100+ employees at a time, leadership and teamwork
building, research, development and implementation of several analytical methods.

Chemical analysis of drinking water, wastewater, groundwater and solids for inorganic and organic
constituents as well as microbilogy. Precious metals recovery, private research projects, expert
testimony, Consumer product testing (CPSIA & CA Prop. 65), RoHS compliance testing and consulting.

SPEACILTIES:

Technical Specialties: Proficient with the following instrumental techniques — ICP-AES, ICP-MS, lon
Chromatography, Gas Chromatography, GC/MS, HPLC, UV/VIS Spectrophotometer, Flame and
graphite furnace atomic absorption, Microbiology, PCM asbestos, and TEM asbestos.

Other Specialties: Authoring standard operating procedures plus quality systems manuals, internal and
external auditing, full knowledge of TNI-NELAC, ISO 17025, A2LA, NYSDOH, NLLAP, GLP, ELPAT
and AIHA certification standards and procedures. Consultant for multiple environmental and industrial
hygiene laboratories to help improve profit margins and achieve or maintain their accreditation's. He
has performed numerous on site assessments for The Department of Defense, Department of Energy,
TNI and |1SO17025 contract assessor for ANSI/ANAB and A2LA.

Current Chairman / President of the Laboratory Association of New Hampshire (LANH) www.lanh.org.
EDUCATION AND TRAINING:

North Eastern University - Chemistry Major- Burlington, MA

Middlesex Community College - Chemistry Major- Burlington, MA

Camden County College - Chemistry Major - Blackwood, NJ

Associates Equivalence Chemistry - Shawsheen Technical School - Billerica, MA
Perkin Elmer Training Course in Atomic Spectroscopy

TAKA and Associates Training Course in Transmission Electron Microscopy (TEM)
PASI Training Course in Phase Contrast Microscopy (PCM)

AMETEK ICP-MS instrument Training

Intermediate Gas Chromatography / Mass Spectroscopy

EPA Cincinnati Ohio Inorganic and Organic Dirking Water Program

ANSI/ANAB Lead Assessor Course

Department of Defense QSM Training

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P272

Board Of Aldermen - Agenda - 5/25/2021 - P273

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
273
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

OQhem erve

ENVIRONMENTAL ANALYSTS

317 Elm Street, Milford, NH 03055 (603) 673-5440 sales@chemservelab.com

EXPERIENCE:
Chemserve, Milford, New Hampshire 08/98 - Present

Director of Operations

Day to day operation of the facility
Profit and Loss

Employee training

Scheduling

Supervision and direction of 20 employee operation
Turnaround time & deadlines
Business development

Human resources & personnel
Data review

Sample analysis

Instrument Repair

Inorganic Lab Manager

e Analysis of environmental samples for metals analysis using ICP and AA techniques as well as lon
chromatography.

Microbiology analysis

Preparation and analysis of environmental samples for wet chemistry techniques.

Data review and quality control.

Conform to and uphold all accrediting agency requirements.

ProScience Analytical Services, Inc., Woburn, MA 06/96 - 08/98

Laboratory Manager

e Preparation and analysis of environmental samples for inorganic and organic analyses.
Preparation and analysis of samples for asbestos using PCM and TEM microscopy.
Developed lab into state and agency certified testing lab.

Managed all aspects of laboratory including technical and operations.

Started company from ground up.

Hygeia ProScience, Inc./ ATC Environmental, Woburn, MA 07/93-06/96

Director of Operations

e Supervision and Direction of a 25 employee environmental laboratory.

e Maintain all certifications and client requirements.

e Payroll, Human resources, quality control, final report review, personnel, client support, collections
and business development.

Laboratory Manager

e Preparation and analysis of environmental samples for metals analysis using ICP and AA
techniques.

e Data validation and report review.

e Supervision and direction of lab staff.

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P273

Finance Committee - Agenda - 2/16/2022 - P23

By dnadmin on Sun, 11/06/2022 - 21:40
Document Date
Thu, 02/10/2022 - 15:14
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 02/16/2022 - 00:00
Page Number
23
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__021620…

NASHUA POLICE DEPARTMENT

1/20/2022

Roll Call Room

Labor

Material

Sub

Equip.

Demotition

Masonry (CBS)

3,333.00

Ceilings (TSC)

660.00

Dumpster

100.00

Masonry

Infill {2) openings 3'x7'

$

350.00

Tooth in new door

$

75.00

Labor

1,040.00

Doors and frames

New Frame and Door (Lang) 3'x?'

$

1,800.00

Reuse & install Hardware

360.00

Paint

65SF biock filler

25.00

(1) HMDoor and frame

4)

150.00

1550 SF new paint (2) coats

930.00

Ceilings

GSA

1,600.00

HVAC

No cost per Rob hanson @4hall

Elecrtical

Gate City

1,270.00

VCT Floor

Strip 7OSSF

Labor

Equip. Rental

NE flooring

Fire Sprinkler

Adjust 6 heads

Kerry

1,280.00

Total Values

1,020.00

2,225.00

9,728.00

Gen Conditions
GL/BR Insurance (.89%)
Bond Cost {1%)

N/A
9.08
10.29

N/A
19.80
22.45

N/A
86.58
98.15

CM Fee (15%)

155.91

340.09

1,486.91

TOTALS

Pin lin | 44

1,195,27

Wie] 44 | 4

2,607.34

11,399.63

Wii}. 1
Ly

OVERALL CHANGE PROPOSAL COST

$ 25,202.25

Page Image
Finance Committee - Agenda - 2/16/2022 - P23

Board Of Aldermen - Agenda - 5/25/2021 - P274

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
274
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

OQhem erve

ENVIRONMENTAL
317 Elm Street, Milford, NH 03055 (603) 673-5440 sales@chemservelab.com

Meeting customer deadlines
Meeting accreditation requirements

ENSR / AnalytiKem, Wilmington, MA 08/88-07/93

Lab Supervisor

Preparation and analysis of environmental samples for metals analysis using ICP and AA
techniques.

Data validation and report review.

Supervision and direction of lab staff.

Organic sample preparation

Wet chemistry analysis

Microbiology analysis of fecal and total coliform, e-Coli, strep,

KEY PROJECTS:

Planned, developed and purchased equipment for the opening of a new environmental and
asbestos laboratory. Negotiated contracts, pricing and arrangements for new clients. Performed
lead analysis for most certified lead inspectors for the state of Massachusetts and the Mass State
Department of Health. Also worked on asbestos projects involving several of the Massachusetts
School Systems.

Implemented strategies and systems to maximize profit while strictly following the guidelines set
forth by the EPA and other accrediting agencies.

Worked with Dionex to develop, troubleshoot and implement working methodology for Perchlorate
analysis method 314.0 now used by the EPA.

Researched, developed and presented to the EPA a working method for a more accurate silver
recovery analysis.

Led the laboratory in its pursuit and attainment of A2ZLA and Consumer Product accreditation by
developing and implementing SOP’s, methodology, and certification requirements.

Helped create better communication and consistency between labs and accrediting bodies as the
LANH President.

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P274

Board Of Aldermen - Agenda - 5/25/2021 - P275

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
275
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

OQhem erve

ENVIRONMENTAL ANALYSTS

317 Elm Street, Milford, NH 03055 (603) 673-5440 sales@chemservelab.com

CV - Heather Marmorstein, Quality Assurance Officer

EDUCATION:

NHCTC — Nashua — Graduated 2007 with AS degree, Liberal Arts

NHCTC — Nashua — Chemistry

Manual Integration Training

Ongoing QA/QC training NELAC Standards analytical methods requirements w/ Chapter 5
Data Integrity and Ethics Training

EXPERIENCE:

Chemserve — Milford, New Hampshire 01/2007 - present

QA Officer

Data validation and report review

State compliance reporting

Internal audits of methods and analysts to ensure compliance with QA/QC manual, SOP’s, and
state and federal requirements.

Coordination, distribution, analysis scheduling for PE sample program

Assist clients with quality and data questions and investigation of all concerns

Coordinate revisions to the QA/QC manual, SOP’s and other training manuals

Maintain the Chemical Hygiene Plan to ensure compliance with OSHA

Inorganic Environmental Chemist /General Chemistry & Microbiology

Analysis of environmental and drinking water samples for metals analysis using ICP, MCV and AA
instrumentation

Preparation and analysis of bacteriological samples

Analysis of perchlorate and anions using ion chromatography

Quality Control and data review

Analysis of environmental and drinking water samples using over 50 different wet chemistry
techniques

Alene Candles Mfg — Milford, New Hampshire 09/1995- 12/2006

Senior R&D Laboratory Technician

Quality Control, Quality Assurance

Process problem solving

Development and delivery of technical training programs
Chemical formulations

Corrective action plans and trend analysis

Technical writing of SOP’s and manuals

KEY PROJECTS:

Planned, scheduled and implemented large bacteriological project for a client, ensuring adherence
to all aspects of quality control.

Metals analysis and quality control of a one year; multi-thousand sample soil project.

Developed method of analysis and QA for Enterococcus analysis

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P275

Board Of Aldermen - Agenda - 5/25/2021 - P276

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
276
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

hemf,erve

ENVIRONMENTAL
317 Elm Street, Milford, NH 03055 (603) 673-5440 sales@chemservelab.com

D. Similar landfill groundwater experience

CURRENT

City of Nashua Landfills
Nashua, NH

Contact: Kerry Converse

Address: 840 West Hollis St.
Nashua, NH 03062

Phone: (603)-594-3420

Chemserve collected and analyzed samples from existing surface and monitoring wells on a semi-
annual basis. The field team performed field analyses using both standard purge and “Low-
Stress” purge techniques. All samples collected from surface water were field filtered for
dissolved metals analysis. All other samples were collected in containers per CFR 40 Part 136
and field preserved for delivery to our laboratory.

38 Groundwater wells and 4 surface waters, Project duration: 9 years (2012-Present).

City of Fall River MA, Riggenbach Rd. Landfill
Fall River, MA

Contact: John Staskowicz

Address: One Gov't Center
Fall River MA 02700

Phone: (508) 324-2500

Chemserve collected and analyzed samples from existing surface and monitoring wells on a
quarterly basis. The field team performed field analyses using standard techniques. All samples
collected from surface water were field filtered for dissolved metals analysis. All other samples
were collected in containers per CFR 40 Part 136 and field preserved for delivery to our
laboratory.

30 Groundwater wells and 3 surface waters
Project duration: 9 years (2012-Present)

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P276

Board Of Aldermen - Agenda - 5/25/2021 - P277

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
277
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

hemf,erve

ENVIRONMENTAL ANALYSTS

317 Elm Street, Milford, NH 03055 (603) 673-5440 sales@chemservelab.com
Town of Wilton Landfill
Wilton, NH

Contact: Rebecca Balke

Comprehensive Environmental Inc
Title: Project Manager
Phone: (800)725-2550 Ext. 308

Chemserve collected and analyzed samples from five monitoring and two surface locations at the
Wilton town landfill. Sampling was performed utilizing the "low flow" collection technique. The field
team performed analyses for pH, specific conductance, temperature, dissolved oxygen, ORP,
static water elevation and turbidity in the field. All samples were collected from surface wells in
containers per 40 CFR Part 136 and field preserved prior to delivery to our laboratory.

Approximate # of Wells: 5
Project Duration: 8 years (2013-Present)

Town of Jaffrey Landfill
Jaffrey, NH

Contact: Randy Haglin/Doug Starr
Title: Director, Dept. of Public Works
Address: 23 Knight St.

Jaffrey, NH 03452
Phone: (603) 532-6521

Chemserve collected and analyzed samples from existing monitoring wells and surface waters on
a bi-weekly basis. The field team performed field analyses for pH, conductivity, temperature, total
well depth, and static depth. All samples were collected in containers per 40 CFR Part 136 and
field preserved prior to delivery to our laboratory.

Approximate # of Wells: 8
Project Duration: 25 years (1993-Present)

Town of Dunstable Landfill
Dunstable, MA

Contact: Joan Ferrari
Box 268
Dunstable, MA 01827
978-649-4514 x229

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P277

Board Of Aldermen - Agenda - 5/25/2021 - P278

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
278
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

hemf,erve

ENVIRONMENTAL ANALYSTS

317 Elm Street, Milford, NH 03055 3972510 sstesacromservetb.com
Chemserve collected and analyzed samples from existing monitoring wells and surface waters on
a yearly basis. The field team performed field analyses for pH, conductivity, conductance, pH and
temperature temperature, total well depth, and static depth. All samples were collected in
containers per 40 CFR Part 136 and field preserved prior to delivery to our laboratory.

Approximate # of Wells: 5
Project Duration: 8 years (2013- Present)

PREVIOUS

Naushon Trust Inc.
Gosnold, MA

Contact: Paul Elias

Title: Trustee

Address: c/o J.M. Forbes & Co.
3 Post Office Square
Boston, MA 02108

Phone: (617) 423-5705

Chemserve collected and analyzed samples from five existing monitoring wells and one drinking
water well on Nonamessett Island in conjunction with a fuel oil release site. Sampling was
performed utilizing the "low flow" collection technique. The field team performed field analyses for
pH, conductivity, temperature, total well depth, static depth. All samples were collected from
surface wells in containers per 40 CFR Part 136 and field preserved prior to delivery to our
laboratory.

Approximate # of Wells: 5
Project Duration: 2 years (2011-2012)

Town of Bellingham Landfill
Bellingham, MA

Contact: Mike Graf

Title: Health Officer

Address: 6 Mechanic St.
Bellingham, MA 02019

Phone: (508) 966-5820

Chemserve collected and analyzed samples from existing monitoring wells on a quarterly basis.
The field team performed field analyses for pH, conductivity, dissolved oxygen, temperature, total
well depth, static depth, and methane. All samples collected from surface wells were field filtered

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P278

Board Of Aldermen - Agenda - 5/25/2021 - P279

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
279
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

hemf,erve

ENVIRONMENTAL
317 Elm Street, Milford, NH 03055 (603) 673-5440 sales@chemservelab.com

for dissolved metal analysis. All other samples were collected in containers per 40 CFR Part 136
and field preserved prior to delivery to our laboratory.

Performed landfill gas field monitoring and sample collection for % LEL, % methane, hydrogen
sulfide, carbon monoxide, carbon dioxide, oxygen and VOCs.

Approximate # of Wells: 15
Project Duration: 19 years (1999-2020)

Town of Milford Sludge Landfill
Milford, NH

Contact: Kevin Stetson

Title: Superintendent, POTW

Address: 1 Union Square Town Hall
Milford, NH 03055

Phone: (603) 673-9441

Chemserve collected and analyzed samples from existing single surface monitoring wells on a
quarterly basis. The field team performed field analyses for pH, conductivity, temperature, total
well depth, and static depth. All samples collected from surface wells were field filtered for
dissolved metals analysis. All other samples were collected in containers per 40 CFR Part 136
and field preserved prior to delivery to our laboratory.

Approximate # of Wells: 4
Project Duration: 10 years (1996-2006)

E. References

City of Fall River MA, Riggenbach Rd. Landfill
Fall River, MA

Contact: John Staskowicz

Address: One Gov't Center
Fall River MA 02700

Phone: (508) 324-2500

Town of Wilton Landfill
Wilton, NH

Contact: Rebecca Balke, Comprehensive Environmental Inc

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P279

Board Of Aldermen - Agenda - 5/25/2021 - P280

By dnadmin on Mon, 11/07/2022 - 07:02
Document Date
Fri, 05/21/2021 - 17:45
Meeting Description
Board Of Aldermen
Document Type
Agenda
Meeting Date
Tue, 05/25/2021 - 00:00
Page Number
280
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/boa_a__052520…

hemf,erve

ENVIRONMENTAL ANALYSTS

317 Elm Street, Milford, NH 03055 3972510 sstesacromservetb.com
Title: Project Manager
Phone: (800)725-2550 Ext. 308

Town of Jaffrey
Jaffrey, NH

Contact: Randy Haglin/Doug Starr
Title: Director, Dept. of Public Works
Address: 23 Knight St.

Jaffrey, NH 03452
Phone: (603) 532-6521

Town of Dunstable Landfill
Dunstable, MA

Contact: Joan Ferrari
Address: Box 268

Dunstable, MA 01827
Phone: 978-649-4514 x229

Page Image
Board Of Aldermen - Agenda - 5/25/2021 - P280

Pagination

  • First page « First
  • Previous page ‹‹
  • …
  • Page 1392
  • Page 1393
  • Page 1394
  • Page 1395
  • Current page 1396
  • Page 1397
  • Page 1398
  • Page 1399
  • Page 1400
  • …
  • Next page ››
  • Last page Last »

Search

Meeting Date
Document Date

Footer menu

  • Contact