2. ASTM D 3161/UL 997 Wind Resistance.
3. ASTM D 3462
E. Shop Drawings: Indicate specially configured metal flashing, jointing
methods and locations, fastening methods and locations and
installation details as required by project conditions indicated.
1.5 QUALITY ASSURANCE
A. Installer Minimum Qualifications: Installer shall be licensed or otherwise
authorized by all federal, state and local authorities to install all
products specified in this section. Installer Installer shall perform work
in accordance with NRCA Roofing and Waterproofing Manual
Work shall be acceptable to the synthetic slate roof tile manufacturer.
B. Mock-Up: Provide a mock-up for evaluation of surface preparation
techniques and application workmanship.
1. Finish areas designated by architect
2. Do not proceed with remaining work until workmanship, color
and pattern are approved by Architect.
3. Rework Mock-Up area as required to produce acceptable
work.
C. Pre-Installation Meeting — Conduct a pre-installation meeting at the site
prior to commencing work of this section: Require attendance of entities directly concerned
with roof installation.
Agenda will include:
1. Installation procedures and manufacturer's recommendations
2. Safety procedures
3. Coordination with installation of other work
4. Availability of roofing materials.
5. Preparation and approval of substrate and penetrations through roof.
6. Other items related to successful execution of work
D. Pre-Installation Meeting: Regulatory Requirments Products must conform with
the following:
1. International Code Council -
E. Maintain one copy of manufacturers application instructions on the project site.
F. Verify that manufacturer’s label contains references to specified ASTM
standards
1.6 DELIVERY, STORAGE, AND HANDLING
A. Store Products in manufacturer's unopened packaging until ready for
installation.
B. Store and dispose of solvent-based materials and materials used with
solvent based materials, in accordance with requirements of local
073113-3