between Carlisle 725TR and an approved substrate.
2.06 METAL EDGING AND MEMBRANE TERMINATIONS
A. General: All metal edgings shall be tested and meet ANSI/SPRI ES-1 standards and comply with
International Building Code. All metal work is to be supplied and warranted by the manufacturer.
B. SecurEdge One Supplied —
1. SecurEdge One Fascia: A snap-on edge system consisting of an extruded aluminum retainer bar,
corrosion resistant fasteners and a 24 gauge or 0.040 Kynar finished aluminum fascia cover. Available
with a 3” fascia height 12’ long. Metal fascia color shall be designated by the Owner’s Representative.
ANSI/SPRI ES-1 Certified.
2. SecurEdge One Edge: A snap-on edge system consisting of a 24 gauge retainer bar, corrosion resistant
fasteners and a 24 gauge or 0.040 aluminum Kynar finished fascia cover. A spring clip holds the fascia
cover in place. Available in sizes up to 8” fascia height 12° long. Metal fascia color shall be designated
by the Owner’s Representative. ANSI/SPRI ES-1 Certified.
3. SecurEdge One Coping: A snap-on coping edge system consisting of a 24 gauge retainer bar (face side
only), corrosion resistant fasteners and a 24 gauge or 0.040 aluminum Kynar finished coping cover. The
coping cover is secured by clipping on the retainer bar and fastened on the backside with corrosion
resistant fasteners (with rubber washer). Available for wall thicknesses up to 30”. Metal coping cap
color shall be as designated by the Owner's Representative. ANSI/SPRI ES-1 Certified.
C. Drip Edge: a metal fascia/edge system with a 22 or 24 gauge continuous anchor cleat and .032 inch thick
aluminum or 24 gauge steel fascia. Metal fascia color shall be as designated by the Owner's Representative.
D. SecurEdge Coping: incorporates a 20 gauge anchor cleat with 4 pre-slotted holes, a concealed joint cover
and 10 foot continuous sections of coping cap; can accommodate minimum 5 “ wide parapet walls. Metal
coping cap color shall be as designated by the Owner's Representative.
E. Termination Bar: a 1” wide and .098” thick extruded aluminum bar pre-punched 6” on center; incorporates
a sealant ledge to support Lap Sealant and provide increased stability for membrane terminations.
2.07 WALKWAYS
Protective surfacing for roof traffic shall be Sure-Seal Pressure-Sensitive Walkway Pads (with Factory-Applied Tape
on the underside of the walkway) adhered to the membrane surface in conjunction with Sure-Seal Primer.
2.08 OTHER MATERIALS
A. As needed
PART 3 EXECUTION
3.01 GENERAL
A. Comply with the manufacturer’s published instructions for the installation of the membrane roofing system
including proper substrate preparation, jobsite considerations and weather restrictions.
B. Position sheets to accommodate contours of the roof deck and shingle splices to avoid bucking water.
3.02 VAPOR RETARDERS
A. None