Communication

Drive Applications Description Offering/range Benefits Acceptance options Cross-reference Enclosure
DE1 e Variable speed starter The DE! variable speed starter (VSS) is designed for customers who have basic applications but Single-phase to Three-phase to Ease of use: Copy/paste tool, programmable multi-function inputs, configuration module for quick programming ¢ Modbus RTU © ABB (ACS Series 55) © Open IP20
still require variable frequency and advanced motor protection. With industry-leading ease of use three-phase three-phase Space-saving design: DIN rail mountable, side-by-side mounting, numerous orientations, small footprint (UL) C 4 IEC © SmartWire-DT Lenze / AC Tech (8400 Series) _
and a narrow, compact housing, the DE1 allows customers to simplify their design and reduce 230 V to 3 hp 480 V to 10 hp a . c © Schneider/Square D (Altivar Series 12)
installation time Efficiency: Temperature controlled fan * Yaskawa J1000
, Rugged and reliable: High overload rating (CT), ambient temperature —10 °C to +60 °C without derating, harmonics mitigating design % © Siemens G110
DOt ¢ General-purpose microdrive The DC1 VFD is a compact VFD with only 14 basic parameters, SmartWire-DT™ connectivity and Single-phase to Three-phase to Ease of use: Only 14 standard parameters for startup—quick commissioning, parameter copy function from drive to drive and PC ¢ Modbus RTU © ABB (ACS 55, 150) © Open IP20, IP66
se | 2 ¢ Machinery OEM drive outstanding ease of mounting and installation. The DC1 is perfect for quick commissioning and is single-phase three-phase connectivity via COM-STICK, integrated info card (UL) C € e CANopen® © Danfoss (Micro Drive, VLT 2800)
a a rs ideal for panel builders. This drive supports single-phase motor applications, and an IP66 offering 115 V to 0.75 hp 230 V to 5 hp Space-saving design: DIN rail mountable, side-by-side mounting, contactor style wiring c © SmartWire™ ® Hitachi (WJ200)
E provides unique mounting with integrated disconnect and cover controls. 230 V to 1.5 hp 480 V to 15 hp Efficiency: Temperature controlled fan v © Yaskawa (J1000, V1000}
we : , © Lenze (SMD, 8400 BaseLine/StateLine
three obese. to Rugged and reliable: Ambient temperature —10 °C to +50 °C without any derating, high protection degree classes: IP66 for LY RoHS e game (6 (Micromaster mene Sr nis G120C)
115 V to 1.5 hp decentralized applications © WEG (CFW-10, CFW-08, CEW-09)
230 V to 5 hp
DA1 = © High-performance microdrive The DA1 VFD is the perfect match for demanding OEM applications. High-performance processor, Single-phase to Three-phase to Ease of use: Only 14 standard parameters for startup—quick commissioning, parameter copy function from drive to drive and PC ¢ DC1 Communications+ e ABB (ACS 150, 355, 550) © Open IP20, IP66
sats ial 2 ® Machinery OEM drive safe torque off, multiple fieldbus protocols including SmartWire-DT, sensorless vector control and three-phase three-phase connectivity via COM-STICK, integrated info card C € @ BACnet/IP® © Danfoss (Micro Drive, VLT 2800)
i “ Yi the possibility to operate permanent magnet motors are sure to leave a lasting impression. The DA1 230 V to 3 hp 230 V to 7.5 hp Space-saving design: DIN rail mountable, side-by-side mounting, contactor style wiring c ¢ PROFIBUS DP ¢ Yaskawa (J1000, V1000)
- P includes an IP66 offering as well. 480 V to 15 hp Efficiency: Temperature controlled fan v e DeviceNet © Schneider (ATV 312, 32)
— — = 600 V to 20 hp ¥: p : 3 on: . . . . LY RoHS © EtherNet/IP © Siemens (Micromaster 420, G110, Sinamics G120C)
Rugged and reliable: Ambient temperature —10 °C to +50 °C without any derating, high protection degree classes: IP66 for decentralized COMPLIANT © ProfiNet * Rockwell/Allen-Bradley (PowerFlex Series 4, 40, 525)
applications, Safe Torque Off, standard brake chopper circuit and RFI © EtherCAT
H-Max e HVAC drive The H-Max™ VFD is specifically designed to meet the needs of the HVAC industry by offering —_— Three-phase to Ease of use: Startup Wizard, graphic display and keypad, menu-based navigation, copy/paste tool, local/remote button, programmable ¢ Modbus RTU/TCP © ABB (ACH550)} © Open IP21, IP54
leading HVAC software and hardware features. With an industry-leading energy efficiency three-phase multi-function |/0, built-in communication protocols (BACnet, Modbus®, N2} (UL) C € OSHPD = « BACnet MS/IP © Danfoss (FC-102) © Open NEMA 1, 12
algorithm, See ae Sohatilty te rating and robust design. Max offers customers increased a \ to ie pp Space-saving design: Narrow enclosure, built-in electronic bypass, open NEMA 12 option C © LonWorks® : gaskawa brsoo| : Encinsed Niet ncder luded)
efficiency, safety and reliability in both an open and enclosed product. 0 p . een 0 . : we iemens ntelliDisconnect (breaker include
Efficiency: Active Energy Control, offering 2-10% energy savings over competition © Vacon (100 HVAC) © IntelliPass (bypass included)
Rugged and reliable: 5% DC choke with MOV protection, conformal coated circuit boards, EMC filters
DG1 ~ © General-purpose drive The DG1 general-purpose drives are part of the Eaton next-generation PowerXL™ series of variable Single-phase to Three-phase to Ease of use: Startup Wizard, four built-in applications, real time clock, on-board communications, modular design, full text display, e EtherNet/IP e ABB (ACS310, ACS550) © Open IP21, IP54
m= frequency drives specifically engineered for today’s more demanding commercial and industrial three-phase three-phase keypad copy/paste functionality (UL) C € IEC ¢ Modbus RTU/TCP © GE (AF-650)} © Open NEMA 1, 12
| *| applications. With an industry-leading energy-efficiency algorithm, high short-circuit current rating 230 V to 40 hp 230 V to 125 hp Space-saving design: Compact design, open NEMA 12 option, on-board I/O expansion provisions C e PROFIBUS DP © Rockwell/Allen-Bradley (PowerFlex 70, 753) © Enclosed NEMA 1, 12, 3R, 7
aa and robust design, the DG1 offers customers increased efficiency, safety and reliability in both an 480 V to 60 hp 480 V to 250 hp a Ditltin Ea : ae . ¢ DeviceNet © Schneider/Square D (Altivar 61, 71) ¢ Consult Eaton for NEMA 4X
| | \ | open and enclosed product. 575 V to 250 hp Efficiency: Built-in 5% DC Link Choke with input surge protection and EMC Category C2 standard ROHS © CANopen © Siemens (Sinamics 120)
. Rugged and reliable: High overload (CT) and low overload (VT) rated, robust time-proven design, durable metal power section, ROP ¢ BACnet MS/TP ¢ Vacon (NXS}
brake chopper circuit, temperature deratings up to 60 °C = © Yaskawa (P1000, A1000)
SVX/SPX = © General-purpose drive The SVX VFD is a general-purpose, compact, modular solution for variable speed applications Single-phase to Three-phase to Ease of use: Startup Wizard, seven built-in applications, customizable software, advanced capabilities and inputs, e EtherNet/IP © ABB (ACS880) © Open IP20, IP21, IP54
mg | ® High-performance drive and offers a variety of features and application capabilities. If high performance is critical to a three-phase three-phase local/remote button, modular design, text display (UL) C € IEC ¢ Modbus RTU/TCP © Rockwell/Allen-Bradley (PowerFlex 700, 755) © Open NEMA 1, 12
el a customer's application, ne srr vip is the ideal choice, They are equipped with high processing a \ ‘0 a pp a \ to yar Space-saving design: Compact design, open NEMA 12 option, on-board I/O expansion provisions c : Roe OP : Sea eure D iatvar 7 5120) : Oe ve 1, 12, *
lu power, capable of closed loop feedback, safe torque off, permanent magnet motor operation an 0 p 0 p . Dales : : : : : eviceNe iemens (Sinamics , , agriculture config
ve a very precise motor control. 575 V to 2300 hp Efficiency: Built-in 3% line reactor and EMI RFI filter H standard, increased microprocessing power © CANopen © Vacon (NXS) © Consult Eaton for NEMA 4X
; y Rugged and reliable: High overload (CT) and low overload (VT) rated, robust time-proven design, durable metal power sectio