217
Turbine Performance Curve and Table for the Jackson Mills Hydroelectric Upgrade
Project Net head= 19.9 ft
eta T(%) Turbine Efficiency and Power Output PT(kW)
100% 1,400
95%
1,200
90%
85% 1,000
80% 800
75%
70% 600
65% 400
60%
200
55%
50% 0
100.00 200.00 400.00 500.00 600.00 700.00 800.00
Q(cfs)
MAVEL KA1800K4 Net Head 19.9 ft
des Unit Turbine Efficiency (36) Unit ae shaft
224.9 89.15% 338
299.9 91.61% 463
374.9 92.65% 585
449.8 93.04% 705
524.8 93.04% 823
599.8 92.58% 936
674.8 91.39% 1039
749.7 89.21% 1127