Technical Data for Hydraulic System and Governor
Component Weights 1102 LBS
Power Requirements 10 kw
Governor Speed Sensitivity +1%
Hydraulic System Working Pressure 2321 PSI
Low Hydraulic Pressure Alarm (Trip) Point 580 PSI
Maximum Permissible Wicket Gate Closure Time 60 SEC
Minimum Time to Open Wicket Gates 60 SEC
Minimum Time to Close Wicket Gates 15 SEC
Wicket Gate Servometer Capacity 34800 LBS
Frce Required to Close Wicket Gates Under Maximum Head at Most Adverse Operating Condition 40345 LBS
Blade Position Servometer Capacity 140400 LBS
Maximum Blade Position Servometer Force Required Under Most Adverse Conditions 160040 LBS
Project No. 0-29029.Rev.3 www.mavel.com Jackson Mills Upgrade