Skip to main content

Main navigation

  • Documents
  • Search

User account menu

  • Log in
Home
Nashua City Data

Breadcrumb

  1. Home
  2. Finance Committee - Agenda - 8/19/2020 - P19

Finance Committee - Agenda - 8/19/2020 - P19

By dnadmin on Mon, 11/07/2022 - 13:27
Document Date
Fri, 08/14/2020 - 12:20
Meeting Description
Finance Committee
Document Type
Agenda
Meeting Date
Wed, 08/19/2020 - 00:00
Page Number
19
Image URL
https://nashuameetingsstorage.blob.core.windows.net/nm-docs-pages/fin_a__081920…

Page 5
Quote no. 20354078

Additional Information

COVID-19

FARO does not assume any risk for (i} late detiveries of goods, (li) customers’ inability or Impracticability to receive or
use our devices or software, and for (ii) delivery disruptions, that are due to the COVID-19 pandamic and ensuing
government measures (shut downs, lock-downs, quarantines),

QUOTE TERMS

To accurately and promptly process your order, the follawing Information is required with your Purchase Order:
1. Purchase Order Number (PO#}

2, Bil To AND Ship To Address (even if they are the same)

3. FARO Approved Payment Terms

4, Prepay and Add Freight Charges OR Collect (with your shippers Account #)
5. Method of Shipment (Best Way, Ground, Overnight, 2DAY)

6. FOB Origin or Destination (for GSA and Warranty ONLY Customers)

7. FARO Quote Number

8. PO Signed and Dated

9. Ship To State Tax Exemption Certificate OR acknowledgement to charge tax
10. Signed Credit Application (New Customers ONLY)

Quoted delivery terms are contingent upon timely receipt of all above listed items,

CALIBRATION CAPABILITIES

FARO meets the calibration requirements of ISOHEC 17625:2005 for USB Arms, Bluetooth Gage, Gages, 3D imager,
LLP and Laser Trackers. Our capabilities are listed on our ISOMEC 17025:2005 Scope of Accreditation and might vary
by location, The scope of each location can be accessed from the FARO website.

CALIBRATION STANDARDS
USB Arms and Bluetooth Gage are calibrated in accordance with ASME B89.4.22-2004.
Other Gage Models are calibrated In accordance with ISO 10360-12:2016.
3D Imager are calibrated in accordance with VDIVDE 2634-2:2012,
Laser Trackers are calibrated in accordance with 889.4.19-2006* as requested by the Customer.
“Part # 960-02589 - System Calibration is an additional calibration process to our Part # ACC-00 - Standard
Calibration.
Quantum S/M Ams are calibrated In accordance with ISO 10360-12:2016.

DECISION RULE

For B89 Calibration, FARO follows the recommendation of the ASME B89.4.22-2004, Appendix J, In the application of
ihe decision rule to testing results. This appendix states "B89 standards that adopt slandards referencing ISO 14253-1
as a nomnative standard shall expliciily state a different decision rule, where the 4:1 simple acceptance and rejection rule
from B99.7.3.1 shail be the default rule unless a different rule is specified."

For ISO 10360-12:2016 Calibration, FARO follows this Standard's recommendation, Introduction Clause, in the
application of the decision rule to testing results. This clause states that “the default decision rules given in ISO 14253-1
apply to specifications made in accordance with this part of {SO 10360, unless otherwise indicated." The relevant
decision rule in ISO 14253-1:2017 Is given in Clause 5.2, “Rule for proving conformance with specifications.” FARO also
follows this decision rule according to the recommendation of VDIA/DE 2634-2:2012, Annex 4.3.5.

CUSTOMS and EXPORT CONTROL

Deliveries of these goods/products, software, technologies, know-how-transfer to other countries (e.g. embargos) or to
other receivers can be subject to authorization or may be prohibited. US-origin goods/products, sofware, technolagies,
know-how-transfer or praducts which include 10/25 % US- origin, are liable to US-Export-Administration Regulations and
could he subject to authorization or may be prohibited.

Page Image
Finance Committee - Agenda - 8/19/2020 - P19

Footer menu

  • Contact