for approval prior to testing. Complete dimensions of the gauge for each diameter of pipe
to be tested shall be in accordance with ASTM D3034.
2. Any section of pipe found to exceed 7.5 percent deflection shall be deemed a failed pipe
and shall be excavated and replaced by the Contractor at his own expense.