Otterbine Barebo Inc.

SYSTEM STARTUP

DO NOT ALLOW THE AERATOR TO OPERATE “DRY” OUT OF THE WATER

IMPORTANT: Otterbine aerators are designed to run in a Counterclockwise direction facing the top impeller end.
Current unbalance for three phase systems shall not exceed 5%.
IMPORTANT: Aérateurs Otterbine sont concus pour fonctionner dans le sens antihoraire regardant I'extrémité
supérieure de la turbine. Courant de déséquilibre pour les trois systémes de la phase ne doit pas dépasser 5%

A. User Control Functions
1. Disconnect Switch

DISCONNECT OFF DISCONNECT ON DISCONNECT TRIPPED
Removes Power to the Aerator for Power Applied, Mode of Indicates a Ground Fault
Maintenance/Servicing/Repair, Operation Now Dependent on the MotorMWiring Short Circuit
Timers are not powered Position of MOA Switch, Or Motor Current Overload
(Time of Day Needs to be Reset) Timers are Operating

M-O-A IN OFF M-O-A IN AUTO M-O-A IN
Aerator & Lighting Allows Automatic MANUAL
Will Not Function, Control of Aerator Turns on Aerator,

Timers are & Lighting by Bypasses Timer
Powered and Timers & Other & Non-Critical
Operating, Control Options Control Functions
GFCl’s may be
Reset

3. GFCI (Ground Fault Circuit Interrupter) operation.

Enable Aerator GFCI first:

a. Power must first be applied to PCC.

b. Turn M-O-A switch to the off (center) position.

c. Press the RESET (ON) button, the green light will come on.
d. Turn disconnect switch clockwise to on (vertical).

CAUTION — UNIT WILL START IF M-O-A IS NOT SET TO OFF.

Enable Lighting GFCI:
a. With power to the PCC and the disconnect switch on. Press the reset button. AERATOR GFCIl

When loss of power to the PCC occurs the aerator will not re-start
automatically when power is restored and the aerator GFCI
will need to be reset.

Test all GFCI’s every 6 months by pressing the TEST (OFF) button.

When testing the aerator GFCI the GREEN light should be on, press “TEST”,
the red light should turn on, the motor controller should trip and the disconnect
handle should be off (horizontal at swing panel).

LIGHTING GFCl

www.otterbine.com
10 75-0073 Rev 08 60Hz Concept 3 1-800-AER8TER