tyca
ice on cow pram ntrey ml ip ges ee op
infegrated Security
COMMERCIAL SALES AGREEMENT TOWN NO. CUSTOMER NO. JOB NO. PONO. ESTIMATE NO,
0069-MANCHESTER, 4-289RQYM
NH
SCOPE OF WORK / SCHEDULE OF PROTECTION
VV. SCOPE OF WORK / SCHEDULE OF PROTECTION (“SOW”): Tyco agrees to install or cause to be installed the Equipment and furnish the Service(s), collectively, the System, on the temis
and conditions set out in this Agreement.
A. Ownership of System and/or Equipment: Direct Sale (equinment to become property of the Customer upon payment of Installation Charges and Fees in full).
B. Services to be Provided (“Services”)
Alarm monitoring and Notification Services: No Service Selected
Video Surveillance Services: No Service Selected
Managed Access Control Services: No Service Selected
Video Equipment: No Service Selected
Quality Service Plan(QSP)Maintenance; Preventive Maintenance/Inspection: No Service Selected
Additional Services: Access Control
C. — Equipment fo be Installed (“Equipment”): Tyco will instal, or cause to be installed, the Equipment (or equivalent}, as set forth in this SOW in Customer's designated facility(ies). As used
herein, “installation” means: (|) affixing all Equipment and materials provided by Tyco at such locations within the facility(ies) as are designated by Customer; (li) providing and pulling
cablesiwires required to connect the Equipment to Customer's Communications Facilities and making such connections; (iif), in the case of a Digital Communicator installation, mount
Equipment and plug into RJ31X phone jack previously installed by Customer; (iv) in the case of radio installation, mount radio Equipment and program Equipment with number furnished by
Customer, (v) providing and installing software/firmware required by the Equipment (vi) performing testing as required to establish that the Tyco Equipment is connected, is functioning
according to its specifications, and is cornmunicating over Customer's Communications Facilities: and (vii) providing user-level training to Customer’s designated representative in the use of
such Equipment.
Qty | Product Name Location
as
Locksmith
~~
4-Door Controller, IP Ready, Accessory Kit, Metal Cabinet w/ Leck
1 | Transformer for KT-400, wire-in, 120 VAC/16.5 VAC (75 VA), UL approved
3 | Surface Screw Mount Magnetic Contact with leads, SPST Switch (Form A), Gray
3 | ProxPro Wiegand, Gray, Keypad, 26 bit keypad output
3 1 T-REX PIEZO NO LOGO, WHITE
D. Scope of Work: This Section is intended for installation use only. Any language contained in this Section that attempts to madify the Terms and Conditions of this Agreement shall be void and
of no effect.
Contact information: Please contact Nick Miseirvitch at (603) 589-3305 or at MiseirvitchN@nashuanh gov
System Operation: Tyco integrated Security shall: A. Install (1) Kantech KT-400 contra! panel in the basement IT room. The KT-400 will be tied into the local area network and will be accessible via
Entrapass software from City Hall. The Door Sirikes will be powered by the on-board power supply. B. Add (3) Doors of Access Control to the system which will include a combination card reader
and keypad, door status contact and request to exit motion detector 1. Main Entry Inner Door 2. Main Entry Outer Door 2. Engine Bay to Office Door C. Program system D. Train end-user on basic
use of the system after installation
Programming Info: Door schedules to be determined by City of Nashua
Site Conditions: Existing site
Existing Equipment: N/A
Customer Expectations: Installation shall take place Monday - Friday between 8am and 5pm
Training Expectations: Tyco technician shail train end-user on basic use of the system after installation
General Camments: N/A
Customer Responsibilities / Tyco Exclusions: City of Nashua is responsible for the following: 1. Provide access to all areas required for installation Monday - Friday between 8am and 5pm 2. Provide
(1) 120V electrical connection for the Kantech KT-400 control panel 3. Provide network connection for the Kantech KT-400 control panel 4. Be available for end-user training with the Tyco technician
at the end of the installation
Documentation Needs: N/A
Contract Notes -
e-Form 8880UE01 (09/2015) Page 2 of 6
© 2015 Tyco. All Rights Reserved