C. A list of telephone numbers for local hospital, location of hospital and/or
emergency squad, local fire department, and the name and telephone
number of the Engineer.
d. A copy of this specification and approved Site Work Plan.
e. A copy of the respirator protection program which conforms to the
requirements of 29 CFR 1926.103.
f. A listing of all employees, by name, social security number and New
Hampshire Asbestos Abatement Worker or Supervisor/Foreperson
Certification Number working on the Project.
g. A legible copy of each assigned employee's State of New Hampshire
Certification Card.
h. A daily sign in/out log which identifies persons by name and State of New
Hampshire Asbestos Certification Number, who are/were at the site, and
the length of the time each spent at the site.
A solid, hinged door with a single cylinder dead-bolt lock shall be installed at the
outside entrance to each Decontamination Facility. Provide a shutter which opens
on make-up air inflow and seals on air flow cessation. This door shall be closed
and locked whenever the Work Area is unattended. Two sets of keys for the lock
shall be distributed to the Engineer.
Ensure that barriers and plastic linings are effectively sealed and taped at all
times, and that the Shower Room floor is watertight. Repair damaged barriers,
and remedy defects immediately upon discovery. Visually inspect the facility at
the beginning of each Work period. The Engineer shall also be allowed to use
smoke generators to test effectiveness of barriers, flow of air through the DF, and
HEPA-exhaust systems.
Maintain emergency and fire exits from the Work Area, or establish alternative
exits satisfactory to local fire officials and the Engineer. The Contractor shall
check exits daily for exterior blockages or impediments to exiting.
The Contractor shall post warning signs in English meeting the requirements of
OSHA 29 CFR 1926.1101 at the outside doorway to the Decontamination Facility
which shall be the only non-emergency entrance into the Work Area. The
Engineer may also request that the Contractor post additional warning signs
around the Work Area or at other potential entrances or exposure points. Warning
signs shall be readily visible to any person attempting to enter the Work Area.
02111-33