Glove Bags: Commercially made bags of 6-mil polyethylene shall be used.
Brands/designs are subject to the Engineer's review and acceptance.
Polyethylene Sheet: Provide flame resistant polyethylene film that conforms to
requirements set forth by the National Fire Protection Association Standard 701, Small
Scale Fire Test for Flame-resistant Textiles and Films. Provide largest size possible to
minimize seams, 6.0 mils thick as required, frosted or black, as indicated.
Waste Containers: The Contractor shall provide 6-mil thick leak-tight polyethylene bags
labeled in accordance with EPA's NESHAPS, OSHA, and DOT regulations.
If the waste material contains sharp edges or may otherwise puncture polyethylene bags,
provide properly labeled drums or other closed, puncture resistant containers for storage,
transportation, and disposal.
Fans and Leaf Blower: The Contractor shall provide leaf blower and one 20" diameter
fan for each 10,000 cubic feet of Work Area volume to be used for aggressive sampling
techniques for clearance air testing by the Engineer.
Filters: Provide cascaded filter units on drain lines from showers or any other water
source carrying asbestos contaminated water from the Work Area or Regulated Area.
Provide units with disposable filter elements as indicated below. Connect so that
discharged water passes through the primary filter and the output of the primary filter
passes through the secondary filter.
Primary Filter - Shall pass particles 20 microns and smaller
Secondary Filter - Shall pass particles 5 microns and smaller.
Hand Power Tools - Shall be equipped with HEPA-filtered local exhaust ventilation if
used to drill, cut into, or otherwise disturb ACM.
Pressure-Differential Recorder - Provide air pressure sensing devices equipped with
recorders for continuous monitoring of Work Area pressure differential. Provide
sufficient quantities of chart paper and maintain devices until completion of Work.
Two Way Radios - Provide General Superintendent and all Work Area Supervisors and
Foremen with compatible two-way radios. Provide Engineer with compatible two-way
radio.
02111-27