Wood Core 5000 Panel/24"

Hot dippect—
galvanized steel
top sheet

Optional cornertock holes

e \

Vf thick high
5 density
: composite core

Top View

BARE CORNERLOCK VERSION

System Performance Criterla

a dipped

galvanized
steel bottom
pan

SPECIFICATIONS

General information
@ Panel weight : 5.66 Ibs. bare.

® 1" thick high density composite core.
@ 1-1/16" inches deep with no covering.
®

Protected from corrosion using a hat dipped
galvanized top sheet and bottom pan.

e@ Class A flame spread rating.

® ULC File Number R16784
UNDERSTRUCTURE OPTIONS
C) 2’ Golt-Tite Stringer [2] Cormeriock

C) 2 Snap-Tite Stringer

() 2’ X 2 Heavy Duty Bolted Stringer

CL) 2'X 4’ Heavy Duty Bolted Stringer

C} 4X 4 Heavy Duty Bolted Stringer

COVERING OFTIONS

Factory laminated with integral trim tile
OJ iM6" HPL

C) 1/8" HPL Color
For additional laminate options contact Inside Sales

Color

Bare Panel Options
C) Bare cornerlock to accept carpet tile application

INTEGRAL TRIM VERSION

System performance criteria are the most important to consider because they represent the performance in a typical installation. Panel only criteria
such as concentrated load is often used to specify floor systems however, the test is not representative of an actual installalion because it is
performed with the panel resting on blocks, not actual understructure.

System Performance Criteria (Tested on Actual Understructure)
System Type SYSTEM STATIC LOADS ROLLING LOADS IMPACT
Panel Understructure| “WEIGHT [“Design* SafetyFactor Uniform | 10Passes 10,000 Passes | LOADS

Loads (min. 2.0} Loads
WC5060/24" Carmertock) 6.90 tbs / ft? 4000 Ibs Pass 250 tbs. /ft® 1000 Ibs 600 Ibs 150 Ibs
Snap-Tite Stringer /| 7.40 Ibs / ft? 1000 tbs Pass 250 ibs./ft? 4000 ibs 600 Ibs 150 Ibs
Boll-Tite Stringer

Heavy Duty Bolted Stringer; 7.60 Ibs / ft? 1250 Ibs Pass 400 Ibs /A* 7200 Ibs 800 Ibs 156 ibs

“Design loads and safety factors are defined in the Technical Resources/Technical Bulletins area of the web-site under “Design Loads”. All other tests
are conductad under CISCA's recommended test procedure for access floors.

Tate ASP Access Floors, Inc.
880 Equestrian Court, Oakville,
Ontario, Canada LGL 6L7

© 2010 Tate ASP Access Floors, Inc.
Rev 3

Page Image
Finance Committee - Agenda - 6/7/2017 - P13

Footer menu

  • Contact