Table 1: PM Tasks Performed

Preventive Maintenance

rT smeeemmmrmernerervenen nomeneeteeESEeTEH

MASTER SITE CHECKLIST i:
SERVERS Levell Level 2
Equipment Alarms Check LED and/or other status indicators for fault conditions. x x
Perfarm recommended diagnostic tests based on server type. x x
Capture Diags Capture available diagnostic logs.
Review UEM events and transport medium types, x *
(microwave/leased line/telco, etc}. Event log review for
persistent types. Verify all NM client applications are operating
NM Client Applications {| correctly.
Perform audit of software media on site. Versions, KC numbers, x x
| Verify System SW CD's types, etc.
Verify backups have been done or scheduled. $2 database (BAR), x x
Complete Backup Centracom CDM/ADM database, etc.
Server Check Disks Perform checkdisk on server hard drives x
Perform Zone Controller switchover. ZC1 to ZC2 and back again x
Verify Redundant ZC's {coordinate with customer).
ROUTERS Levell Level 2
Equipment Alarms Check LED and/or other status indicators for fault conditions. x x
SWITCHES | | Levell Level 2
x x
Equipment Alarms Check LED and/or other status indicators for fault conditions.
Perform recommended diagnostic tests based on switch type. x x
Capture Diags Capture available diagnostic logs.
Verify Redundant Test redundancy in CWR devices. Core router switchover x x
Switches {coordinate with customer).
DOMAIN CONTROLLERS Levell Level 2
x x
Equipment Alarms Check LED and/or other status indicators for fault conditions.
Perform recommended diagnostic tests based on server type. x x
Capture Diags Capture available diagnostic logs.
Perform audit of software media on site. Versions, KC numbers, x x
Verify System SW CD's types, etc.
FIREWALLS Levell Level 2
x x
Equipment Alarms Check LED and/or other status indicators for fault conditions.
Perform recommended diagnostic tests based on server type. x x
Capture Diags Capture available diagnostic logs.
LOGGING EQUIPMENT Levell Level2
x x
Equipment Alarms Check LED and/or other status indicators for fault conditions.