Division 9 — Construction Specifications
Legacy Playground at Labine Park
As Amended per Addendum # 2 issued March 24, 2016
oO
Ow
T~TA™M™OANBPer
1.04
w
1.05
1.06
1.07
ASTM D2047 Standard Test Method for Static Coefficient of Friction of Polish-Coated
Floor Surfaces as Measured by the James Machine.
ASTM D2859 Standard Test Method for Flammability of Finished Textile Floor Covering
Materials.
ASTM E303 Standard Test Method for Measuring Surface Frictional Properties Using the
British Pendulum Tester.
ASTM F1951 Standard Specification for Determination of Accessibility of Surface Systems
Under and Around Playground Equipment.
PERFORMANCE REQUIREMENTS
Flammability (ASTM D2859): Pass.
Tensile Strength (ASTM D412): 60 psi (413 kPa).
Tear Resistance (ASTM D624): 140%.
Water Permeability: 0.4 gal/yd2/second.
Accessibility: Comply with requirements of ASTM F1951.
Dry Static Coefficient of Friction (ASTM D2047): 1.0.
Wet Static Coefficient of Friction (ASTM D2047): 0.9.
Dry Skid Resistance (ASTM E303): 89.
Wet Skid Resistance (ASTM E303): 57.
SUBMITTALS
General: Submit listed submittals in accordance with Conditions of the Contract and
Division 1 Submittal Procedures Section.
Product Data: Submit manufacturer’s product data and installation instructions.
Verification Samples: Submit manufacturer’s standard verification samples of 9" x 9"
minimum.
Quality Assurance/Control Submittals: Submit the following:
1. Certificate of qualifications of the surfacing installer.
Closeout Submittals: Suomit the following:
1. Warranty documents specified herein.
QUALITY ASSURANCE
Utilize an installer trained and approved by the manufacturer, having experience with
other projects of the scope and scale of the work described in this section.
DELIVERY & STORAGE
Deliver materials in manufacturer's original, unopened, undamaged containers with
identification labels intact.
Store materials protected from exposure to harmful environmental conditions and at a
minimum temperature of 40 degrees F and a maximum temperature of 90 degrees F.
PROJECT SITE CONDITIONS
Install surfacing on a dry sub-surface with no prospect of rain within initial drying period,
and within 40 degrees F and 90 degrees F.