A. Manufacturer's Qualifications: Manufacturer shall meet a minimum of 1 of the
following 2 requirements.
1. Continuously engaged in manufacturing of playground safety surfacing tiles of
similar type to that specified, with a minimum of 10 years successful experience.
2. Furnished a minimum of 15,000,000 square feet of playground safety surfacing
tiles of similar type to that specified.

B. Installer's Qualifications:
id. Certified by manufacturer for installation of playground safety surfacing tiles.
2) Approved by manufacturer.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Delivery: Deliver materials to site in manufacturer's original, unopened containers and
packaging, with labels clearly identifying product name and manufacturer.

B. Storage:
I: Store materials in accordance with manufacturer's instructions.

2, Playground Safety Surfacing Tiles:
a: Store tiles in a dry area at a minimum temperature of 50 degrees F (10
degrees C) for a minimum of 72 hours before installation.
b. Protect tiles from direct sunlight before installation.
3. Adhesive: Store adhesive in a dry area at a minimum temperature of 50 degrees F

(10 degrees C).

C. Handling: Protect materials during handling and installation to prevent damage.

Ld ENVIRONMENTAL REQUIREMENTS

A. Tile Temperature: Ensure surface temperature of playground safety surfacing tiles is a
minimum of 50 degrees F (10 deqrees C) at time of installation.

B. Air Temperature: Ensure air temperature is a minimum of 40 degrees F (4 degrees C) for
a minimum of 24 hours before and during installation.

G Tile or Air Temperatures: Consult manufacturer's installation instructions for modified
installation procedure when tile or air temperatures are above 85 degrees F (29 degrees

C).