37. Limit Switches:
38. Limit Cams
39. Pit Stop Switch:
40. Pit Ladder:
LANDING ENTRANCES:
41. Frames:
42. Door Panels:
43. Header & Struts:
44. Sills:
45. Gibs:
46. Fascia:
47. Dust Covers:
48. Handicap Plates:
49. Landing Hangers/Track:
50. Interlocks:
51. Door Closers:
CAR DOOR EQUIPMENT:
52. Door Operator:
53. Door Protection:
Proposal # 6021
Ref Id: Mod-09686 - 6/22/2016
| Stanley
Elevator Company, inc,
Remove Existing-/nstall New Top/Bottom Limit Switches & Mtg
Hardware
Retain Existing Limit Cam Assembly
Provide New if Required
Retain Existing Pit Ladder
Retain Existing Entrance Frames
Retain Existing Door Panels
Retain Existing Headers and Struts
Retain Existing Sills
Replace Gib Assemblies With New, Two (2) Per Panel
Retain Existing Fascia and Mounting Hardware
Retain Existing Dust Covers
Replace Existing Braille Plates as required
Remove Existing and Install New Formed Steel Landing Hanger
and Tracks
Remove Existing and Install New Electromechanical Hoistway Door
Interlocks
Remove Existing Closers and Install New Sill Mounted Spring
Landing Door Closers
Remove Existing and Install New GAL MOVFR Closed Loop Solid
State Door Operator
Remove Existing and Install New Solid State Detector Screen
System
Page 5 of 13