148
Replace ex. CB with
new 4' dia. CB with
Install 24" culvert tg :
: hood and 8” PVC tie
PNG, DPE. or , into main (~18').
RCP) inside existing
stone box (over Plug and abandon
sewer main) to outlet pipe.
maintain drainage
flow, construct
headwalls at each
end of pipe culvert to
match to ex. stone
box.
fe Point repair to 15°
>| collapsed clay tile
@ | pipe (abandoned?)
Replace ex. CB with
new 4' dia. CB with
hood and 8" PVC tie
into main (~5'). Plug
and abandon outlet
pipe.
Install 12" PVC sewer
main (~60') to replace
partially collapsed
12" concrete main,
connect to brick
sewer main in Main
Street and PVC
sewer main stub from
Park Street manhole