ORDINANCE O-21-045
§ 105-17. Amendments.
A.
B.
Amend Section 101.1 by inserting: the City of Nashua.
Amend Section 106.6.2 by changing it to read:
106.6.2, Fee schedule. The fees for plumbing work shall be as provided for by
this chapter.
Delete Section 106.6.3.
Amend Sections 108.4 and 108.5 by adding the following statement:
In place of the insertions in the model code text, it shall be clearly understood that
all violations of the adopted codes of the City of Nashua shall be subject to the
provisions of NRO Chapter 74 and RSA 676:15-17-b, without limitation of any
remedy available to the City of Nashua at law or equity.
Amend Section 305.6-+ 305.4.1 by inserting in the places provided, in the order of
appearance, the following:
36 inches (914.4 mm) Pertains to building sewers serving septic systems
48 inches (1,219.2mm) Pertains to other building sewers
Also amend Section 383-64 305.4.1 at the end of the section by adding the
following:
Where insulated, the Code Official may accept lesser depths of building sewer
placement.
Delete Section 501.6 and replace with the following:
501.6. Water temperature control in piping from tankless water heaters. The
temperature of water from tankless water heaters intended for domestic or
personal hygiene use shall be a maximum of 130° F. (55° C.). A tempering device
conforming to ASSE 1017 shall be installed to control the water temperature. This
provision shall not supersede the requirements for protective shower valves in
accordance with Section 424.4.
Amend Section 501.8 by adding the following sentence to the end of the section:
Water temperatures supplying faucets for domestic or personal hygiene use shall
be limited to a maximum of 130° F. (55° C.).
Amend Section 501 by inserting the following new subsection:
501.9 Minimum water heater temperatures, Water heaters and indirect-fired
hot-water storage tanks shall be maintained at a minimum temperature of 140° F.